주요 콘텐츠로 건너뛰기
이미지
보라색 육각형 패턴

Software Upgrades

HSM Patch file provided by SafeNet, bash-4.1.2-15.el6_5.2.i686

SafeNet security bulletin 140925-4 / vulnerabilities BASH Shell patch file

HSM Patch file provided by SafeNet, bash-4.1.2-15.el6_5.2.i686

Affina Data Preparation 1.5 or Affina One Step 1.5 replacement scripts

The data generation scripts for M/Chip4, M/Chip4 MICA, and VSDC shipped with Affina Data Preparation v1.5 or Affina One Step v1.5 have a defect in DDA data generation whereby: the ICC Public Key certificate is incorrectly formatted when the issuer key pair and ICC key pair are different sizes; and/ or the dedicated PIN Encipherment Public Key certificate is incorrectly formatted when the issuer key pair and the dedicated PIN key pair are different sizes. There is no impact on the personalization activity of the software. In addition, there is no impact on previous versions of Affina Data Preparation or Affina One Step. Released August 2010.

Affina Data Preparation 1.5 or Affina One Step 1.5 replacement scripts

Affina® Personalization Manager v4.0 Hotfix F

This hotfix fixes an intermittent communication issue between APM server and DC9000/7000/500 smartcard module. Released December 19, 2007.

Required For
The hotfix is applied to the DC9000 controller PC and SDK installation. It will work with any Affina Personalization Manager 4.0 installation. Required only for users running GenX or 9000 contactless modules that have the issue listed.

Fixed Issues
This hotfix fixes an intermittent communication issue between APM server and DC9000/7000/500 smartcard module. The communication issue causes error message 'SC02002 - 03 Smartcard The user application is no longer running in a program station' displayed on CIS screen and the only method for recovery is to reboot the CIS.

From APM server event log, you will see following event recorded. 'Incoming msg with step x dropped – expected x+1 [mch: MACHINE NAME mod: MODULE NUMBER sta: STAn ip: IPADDRESS:PORT number]'

Instructions
Download the file at the link below. Unzip and view the readme.txt file for further instructions.

Affina® Personalization Manager v4.0 Hotfix F

Affina® Desktop Utility 2.0 Hotfix C

This is a Hotfix for Datacard® Affina® Desktop Utility version 2.0 for compatibility with Syntera Customization Suite version 5.1. Released July 16, 2009.

Required For
Desktop Utility 2.0 Hotfix C is required when running with Syntera Customization Suite v5.1, which must be installed before installing and configuring Desktop Utility 2.0 Hotfix C.
Desktop utility 2.0 Hotfix C should not be used when running with Affina Personalization Manager 4.0, SP1 or older software.
The hotfix should be applied to the desktop client workstations where Desktop Utility 2.0 is installed.

Issues Addressed
Desktop Utility 2.0 Hotfix C includes the following changes:

  • Implements a change for compatibility when running with Syntera Customization Suite v5.1.
  • Resolves an issue that prevented proper operation Key Server key readers.
  • Changes machine registrations to use the name of the computer instead of its IP address.
  • Adds a registry option to suppress the display of some error messages.

Instructions
Download the file at the link below. Unzip and view the readme.txt file for further instructions.

Affina® Desktop Utility 2.0 Hotfix C

Affina® Desktop Utility Time-out Hotfix

This is a Hotfix for Datacard® Affina® Desktop Utility Software v2.0. Released November 2, 2006.

Required For
The hotfix should be applied to the desktop client workstations where the Desktop Utility v2.0 is installed. This hotfix is independent of other hotfixes.

Fixed Issues
There is a Time-out value for the Virtual9000 registry key that can cause numerous issues, but is not documented. Having the setting too low can cause cards to be rejected and may cause data integrity problems. Since the setting affecting this is in registry and not documented it would be difficult for the customer to figure out the problem if an issue occurs. The problem doesn't actually cause cards to fail unless the data is card dependent and the data and card get out of sequence with each other. The problem does cause records on ID Works to get rejected, but they only really show up as TIME-OUT value for the Print Result field in the audit data and not as the actual cards getting rejected.

Instructions
Download the file at the link below. Unzip and double-click the V9000_TimeOut_New.reg file on each client PC. This hot fix should be installed on client PCs running the Desktop Utility 2.0 software. There is no uninstall for the hotfix — it is simply a registry change.

Affina® Desktop Utility Time-out Hotfix

Affina® Personalization Manager Desktop Utility Software v2.0 Hotfix B

This is a Hotfix for Datacard® Affina® Desktop Utility Software v2.0 Released September 12, 2006.

Required For
Desktop Utility 2.0 Hotfix B is required when parsing configurations need to specify fields not in order. This includes the situation where one input data field needs to be used as two different parsed data fields. An example of this is using the mag stripe input field as both the mag stripe and the smart card data, as is required for parsing data generated by Affina Data Preparation.
Desktop utility 2.0 Hotfix B is recommended for all Desktop Utility 2.0 sites that use the Data Parser.
The hotfix should be applied to the desktop client workstations where Desktop Utility 2.0 is installed.

Fixed Issues

  • "Multi-card data with multiple fields not parsed correctly." If a parsing configuration specifies fields not in order and multiple fields, then multi-record data files were not properly parsed, although no errors were detected or returned.
  • "Fields in order is checked by default but not saved." When a new parsing configuration is created, fields in order is checked by default, but in some circumstances the new configuration would be saved with fields not in order specified.

Instructions
Download the file at the link below. Unzip and view the readme.txt file for further instructions.

Affina® Personalization Manager Desktop Utility Software v2.0 Hotfix B

SCPM v3.3 Hotfix F

Changes the default command sent by the Application Configuration utility for HSM testing to be compatible with the Thales HSM8000, while still retaining compatibility with Thales RG7100, CM250, CM200, and CM100 HSMs.

Released February 2008

Issues Addressed:
The command sent by the Application Configuration utility for HSM testing was incompatible with the Thales HSM8000, causing the HSM to reject the command and the test to fail. SCPM 3.3 Hotfix F fixes that problem while retaining compatibility with Thales RG7100, CM250, CM200, and CM100 HSMs.

Required For: SCPM 3.3 Hotfix F is required for installations that use Thales HSM8000HSMs.

The hotfix should be applied to SCPM 3.3 server installations where Communicator runs and the Application Configuration utility is used. It does not apply to Maxsys/MX/PB controller PC installations.ove is used.

Instructions
Download the file at the link below. Unzip and view the readme.txt file for further instructions.

SCPM v3.3 Hotfix F

SCPM v3.3 Hotfix E

This hotfix allows SCPM applications return up to 950 bytes of data as audit trail when running with DC9000 11-station smartcard module. 750 bytes was the limit before this fix.

In order to get 950 bytes for audit you need to use the new 11-station firmware which is "9000 FSC Interface 855T Ver. 0.5". Without using this new firmware, only 750 bytes of data will be returned as audit trail.

SCPM v3.3 Hotfix E